Quick Overview
  • Oxidises Iron*, Manganese Or Hydrogen Sulfide in Water
  • Single Tank Aerator - No Need for Storage
  • Inbuilt Air Filter to prevent contamination
  • Ideal for oxidation pre-Macrolite® Filter
  • 19-30L/Min flow rate for oxidation
A$2,400.00

Kinetico Aeration Venturi System

The Kinetico Aerator is one method for removal of iron, manganese and hydrogen sulphide. Air is introduced into the water stream, promoting oxidation. Oxidation converts soluble iron and manganese to insoluble compounds, which precipitate out and collect in the bottom of the tank and/or are removed by an appropriate filter downstream.

Application

The Kinetico Aerator uses a 13” x 54” tank with a special top closure to hold a vent pipe and service flow riser tube. In high flow rate applications, it may be necessary to use multiple units in parallel. The maximum flow rate supported is 8 gpm for each Aerator.

There are two methods available for putting air into the system: 1) a venturi, where air is drawn in by passing the water through a venturi, or 2) an air pump where air is forced into the water stream.

The venturi requires a minimum pump flow rate of 5 gpm and should not be used with a jet pump (a jet pump usually pumps below 5 gpm). An air pump has no limits on flow rate from the well pump and may be used with jet pumps.

It is recommended that a drain/flush valve be installed at the bottom of the reactor tank to periodically allow the flushing of precipitated particles.

Operation

Water enters the reaction tank through the water inlet.

As water is pumped into the reaction tank, air is mixed with the water stream by the venturi. Oxidation occurs in the reaction tank, and insoluble oxidised compounds precipitate out.

The air vent has two purposes: 1) to vent excess air and hydrogen sulphide gas, and 2) to allow an air pocket at the top of the tank to help with the oxidation process.

Water is drawn up through the service flow riser tube and out through the water outlet.

Iron & Manganese Removal

The Macrolite® system can be used after the Kinetico Aeration system on water that has higher levels of iron & manganese. The aeration will accelerate the oxidation and conversion of iron into ferrous iron which the Macrolite® filter can capture and then backflush to waste. Certain water conditions are required so please contact us prior to purchase. A water analysis is recommended.

System Components

Media Vessel (qty) Size ........................................................ (1) 13 x 54”
Media Vessel Construction ...... Fiberglass Wrapped Engineered Plastic
Empty Bed Volume ...................................................................... 3.59 ft3
Riser Tube....................................................................................1” ABS
Inlet Water Quality
Pressure Range .................................... 15 – 125 psi Dynamic Pressure
Temperature Range............................................................. 35 – 120o F
pH Range.......................................................................... 6.0 – 10.0 SU
Operating Specs
Flow Range ........................................................................ 5.0 - 8.0 gpm
Dimensions (width x depth x height) ...................................13 x 13 x 54”
Weight (Operating / Shipping).............................................350 / 120 lbs
Connections
Inlet Connection .........................................................................1” Union
Outlet Connection .......................................................................1 FNPT
Power..............................................................................................None
System Part Numbers
Aerator ............................................................................................ 6789

Due to the nature of the products we sell, a strict return policy is in place. We work with food grade certified materials that must be un-opened and un-used as to be able to be re-sold.

You will receive a credit of equal amount, less the postage cost to send it to you. 

  • Wrongly purchased items may be returned for a merchandise credit, this applies for but not limited to: Wrong size, wrong system etc.
  • 30 Day return Policy: We will accept returns up to 30 days after the initial purchase, all orders should be checked immediately for damage/fault upon arrival to aid us with the return process.
  • Return shipping is to be paid by the buyer to the address provided
  • Should the item appear faulty or doesn’t work how described, the unit/item must be returned for testing (if requested), the return postage paid by the buyer. If the unit/item is deemed to be faulty, compensation will be provided for the postage cost. If the unit/item is deemed to be in working order and as described, the buyer will need to pay for return postage. 

If you have any questions about our return policy, please contact us before purchase. This will also help to ensure you purchase the correct product that suits your requirements.

More Information
Product Type N/A

Installation / Instruction

apex-logo
jg-logo
pentak-logo
Haycarb-logo
omnipure-logo
uvg-logo
pure-lite-logo
Hydrasil-logo
Blue-logo
Molytec-logo
FSA-de-min-logo
THERMAX-logo