Quantcast

FREE SHIPPING AUSTRALIA WIDE

Free shipping on all retail orders

AUSTRALIAN OWNED & OPERATED

Licenced WaterMark Supplier

WERO Industrial Reverse Osmosis Water Filter 1500GPD – 12000GPD Brackish Water Systems

In stock
SKU
WERO-1500-12000
$16,000.00
- +

WERO Industrial Reverse Osmosis Water Filter 1500GPD – 12000GPD Brackish Water Systems

The WERO range of reverse osmosis machines have been designed in Australia and is perfect for all applications where pure water is required. Designed with standard features that include stainless steel frames, Australian standard compliant electrical system, Danfos pressure switches, Imperial sch80 PVC pipework, stainless steel pumps and housings. The WERO range has been built with ease of operation in mind

RO performance will vary depending on raw water quality and temperature, Please contact us with your water analysis results so we can size the correct size system for your needs prior to purchasing a unit to ensure the system will perform according to specifications

System Options

  • WERO 4-1 (1500 GPD) (250L/hr) [ These are special order items 2-3 weeks lead time ]
  • WERO 4-2 (3000 GPD) (500L/hr)  [ These are special order items 2-3 weeks lead time ]
  • WERO 4-4 (6000 GPD) (1000L/hr) [ These are special order items 2-3 weeks lead time ]
  • WERO 4-6 (9000 GPD) (1500L/hr) [ These are special order items 2-3 weeks lead time ]
  • WERO 4-8 (12000 GPD) (2000L/hr) [ These are special order items 2-3 weeks lead time ]

Key Features

  • 4040 Membrane Housings
  • 304 Stainless Steel Frame, Pump, SS316 Optional**
  • Schedule 80 uPVC pipes
  • 304 Stainless housing standard, SS316 or FRP Membrane housing optional**
  • WERO ROC Controller & Conductivity Meter
  • 240v AC Supply
  • Main Isolation Switch – Interlock On Door
  • Barrel Unions Pre And Post Components
  • Adjustable Levelling Feet
  • Flow Adjustable Needle Valves
  • Float Level Control Option Standard
  • Manual Override Switches In Control Panel
  • Low Pressure Feed Safety Switch
  • RO Flush and Recovery Adjustable
  • Recirculation Option Standard
  • CIP Connections
**Please contact us for 316 Stainless Steel Upgrade Options
 

Specifications

WERO 4-1

Flow Rate  - 250L Per Hour

Temperature – 20 Deg

Operational Pressure  - 1000 kPA

Water Quality* - >2000TDS

Salt Rejection – up to 98%

Dimensions - 700mm(W) x 600mm (D) x 1640(H)

Hydraulic connections -3/4’ inlet PVC x 1/2” outlet PVC x 1/2” Drain PVC

Power consumption - .75 KW

Voltage - 240V AC

Conductivity Monitoring - Feed water and post membranes

Pre Treatment connections - Interface paused during backwash and regeneration cycles

Alarm Notification - Low Pressure feed. Low feed tank level. High conductivity. Permeate tank high level

1 x 4040 Membrane Housing

20 x 2.5” Pre-Filter Housing

WERO 4-2

Flow Rate  - 500L Per Hour

Temperature – 20 Deg

Operational Pressure  - 1000 kPA

Water Quality* - >2000TDS

Salt Rejection – up to 98%

Dimensions - 700mm(W) x 600mm (D) x 1640(H)

Hydraulic connections -3/4’ inlet PVC x 1/2” outlet PVC x 1/2” Drain PVC

Power consumption – 1.5 KW

Voltage - 240V AC

Conductivity Monitoring - Feed water and post membranes

Pre Treatment connections - Interface paused during backwash and regeneration cycles

Alarm Notification - Low Pressure feed. Low feed tank level. High conductivity. Permeate tank high level

2 x 4040 Membrane Housing

20 x 2.5” Pre-Filter Housing

WERO 4-4

Flow Rate  - 1000L Per Hour

Temperature – 20 Deg

Operational Pressure  - 1000 kPA

Water Quality* - >2000TDS

Salt Rejection – up to 98%

Dimensions - 900mm(W) x 600mm (D) x 1640(H)

Hydraulic connections -3/4’ inlet PVC x 1/2” outlet PVC x 1/2” Drain PVC

Power consumption – 2.0 KW

Voltage - 240V AC

Conductivity Monitoring - Feed water and post membranes

Pre Treatment connections - Interface paused during backwash and regeneration cycles

Alarm Notification - Low Pressure feed. Low feed tank level. High conductivity. Permeate tank high level

4 x 4040 Membrane Housing

20 x 4.5” Pre-Filter Housing

 

WERO 4-6

Flow Rate  - 1500L Per Hour

Temperature – 20 Deg

Operational Pressure  - 1000 kPA

Water Quality* - >2000TDS

Salt Rejection – up to 98%

Dimensions – 900mm(W) x 800mm (D) x 1640(H)

Hydraulic connections -3/4’ inlet PVC x 1/2” outlet PVC x 1/2” Drain PVC

Power consumption – 2.5 KW

Voltage - 240V AC

Conductivity Monitoring - Feed water and post membranes

Pre Treatment connections - Interface paused during backwash and regeneration cycles

Alarm Notification - Low Pressure feed. Low feed tank level. High conductivity. Permeate tank high level

6 x 4040 Membrane Housing

20 x 4.5” Pre-Filter Housing

WERO 4-8

Flow Rate  - 2000L Per Hour

Temperature – 20 Deg

Operational Pressure  - 1000 kPA

Water Quality* - >2000TDS

Salt Rejection – up to 98%

Dimensions - 1200mm(W) x 600mm (D) x 1640(H)

Hydraulic connections -1’ inlet PVC x 3/4” outlet PVC x 1/2” Drain PVC

Power consumption – 3.0 KW

Voltage - 240V AC

Conductivity Monitoring - Feed water and post membranes

Pre Treatment connections - Interface paused during backwash and regeneration cycles

Alarm Notification - Low Pressure feed. Low feed tank level. High conductivity. Permeate tank high level

8 x 4040 Membrane Housing

20 x 4.5” Pre-Filter Housing

WERO1500BW.pdf (149.07 kB)
WERO3000BW.pdf (171.74 kB)
WERO6000BW.pdf (171.51 kB)
WERO9000BW.pdf (148.90 kB)
WERO12000BW.pdf (146.56 kB)

Return Policy

Due to the nature of the products we sell, a strict return policy is in place. We work with food grade certified materials that must be un-opened and un-used as to be able to be re-sold.

You may receive a refund or credit of equal amount, less the restocking fee if applicable and any other deductions that are relevant.

  • Wrongly purchased items may be returned for a merchandise credit, this applies for but not limited to: Wrong size, wrong system etc.
  • 30 Day return Policy: Returns will not be accepted without prior approval or after 30 days of invoice date.
  • All returns will incur a 17.5% restocking fee or cost to send the item to you whichever greater. FSA may use discretion to determine the restocking fee.
  • Any damages (minor, that can be repaired) will incur a fee which will be deducted from the total refund which will be equal to the cost of the replacement
    parts (List Price) and labour charge (if applicable) to repair the system(s). This will be separate to the restocking fee.
  • Any damage considered to be major and not feasible for repair may be refused and the return request will be void. The customer will be responsible for the return freight or disposal of the damaged unit.
  • Return shipping is to be paid by the buyer to the address provided. It is recommended that the customer applies transit warranty to the return freight in case of damage.
  • Any damages to the system that were not reported to FSA within 48 business hours of receipted delivery are not covered under our transit warranty.

  • Should the item appear faulty or doesn’t work how described, the unit/item must be returned for testing (if requested), the return postage paid by the buyer. If the unit/item is deemed to be faulty, compensation will be provided for the postage cost (Proof of cost required). If the unit/item is deemed to be in working order and as described, the buyer will responsible for return postage.

If you have any questions about our return policy, please contact us before purchase. This will also help to ensure you purchase the correct product that suits your requirements.